WATERWAY WEATHER BARRIER 9714

Description
WaterWay 9714 is a nominal 3/16 inch thick drainage product consisting of a nylon core of fused entangled filaments and a geotextile fabric bonded to one side. WaterWay 9714 is designed for use with traditional stucco, EIFS, cultured stone, and other wall cladding applications as an exterior wall drain. The rainscreen provides a drainage path & ventilation for incidental moisture between exterior wall finish materials and weather resistive barriers.

Recommended Applications

  • WaterWay Drainable Stucco Assembly
  • Behind EIFS
  • Behind Traditional Cement Stucco
  • Cement Siding
  • Behind Cultured Stone
  • Lap Siding

Features and Benefits

  • Excellent Durability – Class “A” Fire Rated
  • Surpasses EIFS / AC-24 Drainage Criteria
  • Conforms to irregular surfaces with complete and effective coverage
  • Continuous flow even under high loads
  • Long rolls reduce installation costs by eliminating interlocking and excessive seams
  • Dimensionally stable in hot weather – remains flexible in cold
  • Continuous ventilation when properly designed – Equalizes pressure
  • Redirects & draws moisture away from vulnerable wall sheathing materials
  • Filter fabric assures an uninterrupted drain path that remains clear of stucco or mortar

Technical Data

Typical Physical Properties USA (Metric) Waterway 9714
Core Material
Nylon 6
Total Thicknessinches (mm) 0.17   (4)
Total Weightoz/yd2 (g/m2) 10.50   (357)
Fabric Weightoz/yd2 (g/m2) 3.53 (120)
Matrix Weightoz/yd2 (g/m2) 6.00 (204)

 

Standard Packaging Information

Product USA (Metric) WaterWay 9714
Width (less flap) inches (cm) 39.0 (99.1)
Width (with flap) inches (cm) 42.0 (106.7)
Length feet (meters) 151.0 (46.0)
Area yd2 (m2) 54.6 (46.0)
Roll Diameter inches (cm) 19.5 (49.5)
Gross roll weight lbs (kg) 40.0 (18.1)

 

AC24* Drainage test

Time Vert. Horiz.
Calibration* 2.21 Gal. 2.25 Gal.
15 Min. 0.33 Gal. 0.34 Gal.
30 Min. 0.76 Gal. 0.77 Gal.
45 Min. 1.19 Gal. 1.22 Gal.
60 Min. 1.63 Gal. 1.66 Gal.
75 Min** 2.06 Gal. 2.10 Gal.
135 Min. 2.15 Gal. 2.19 Gal.
Efficiency*** 97.63% 97.47%.

* Water flow without drain mat for 75min.
** Water flow turned off.
*** Test requires 90% min.
****According to ICBO ES “Acceptance Criteria for Exterior Insulation & Finish Systems” AC24 Section 6.11 Oct. 1999.
(Average time from first water to first drain over 8 ft. Wall Panel is 91.5 seconds)

 

Deflection & Compression

PressureWaterWay 9714
Inches(mm)
100 psf 0.160 (4.07)
200 psf 0.159 (4.04)
300 psf 0.158 (4.01)
400 psf 0.148 (4.01)
500 psf 0.157 (3.99)
1000 psf 0.151 (3.84)
2000 psf 0.133 (3.38)
4000 psf 0.072 (1.83)

 

Flow Gal/Ft/Min

Pressure9714
250 psf 5.54
500 psf 5.39
1000 psf 5.07
1500 psf 4.48
2000 psf 3.95
2500 psf 3.60
3000 psf 2.83
4000 psf 1.73

 

Geotextile Fabric Properties

Test Method USA (Metric)WaterWay 9714
Polymer   PA6 & PET
Weight ASTM D 5261 oz/yd2 (g/m2) 3.2 (119)
Grab strength ASTM D 4632 lbs (N) 125.0 (556)
Grab elongation ASTM D 4632 % (%) 40.0 (40)
Trapezoidal tear ASTM D 4533 lbs (N) 40.0 (178)
Puncture resistance ASTM D 4833 lbs (N) 35.0 (155)
Mullen burst ASTM D 3786 psi (Kpa) 160.0 (1102)
AOS (maximum average) ASTM D 4751 (mm) (.357)
Flow rate ASTM D 4491 gpm/ft2 (l/sec/m2) 185.0 (125)
Permittivity ASTM D 4491 sec-1 (sec-1) 2.5 (3)
Fabric color Gray

 

Installation Procedure
These suggestions represent generally accepted procedures for successful installation. It may be followed, modified, or rejected by the owner, engineer, contractor or their representative to accommodate project specific requirements.

Prior to installation the contractor’s responsibility is to ensure that:

  1. The substrate is sound, that there are no voids or other protrusions or conditions that would interfere with the drainage plane. Acceptable sheathing types include code compliant exterior grade plywood, oriented strand board, water-resistant gypsum and others. Consult your local building code for approved materials.
  2. The substrate is flat or plumb within 6.4mm (1/4 inch) in a 1.2m (4-foot) radius.
  3. Windows and doors have been properly flashed and sealed and also that roof flashings have been properly installed. Refer to “Installation Guide for Flashing Windows/Doors ETF 201” latest edition (Available upon request).
  4. Weather resistive barrier is properly installed to allow drainage without water penetration.

Attachment to Sheathing with Weather Resistive Barrier

  1. For wall application work from bottom to top. Attach fabric side out with flap down to assure proper shingling. Wrap the building completely, butt tightly at all door, window and other building materials (electrical boxes, air conditioning units, etc...), stopping at all wall ends. Install drainage mat so that it lies flat against the wall with adequate corrosion resistant fasteners to hold in place until cladding material application is complete.
  2. If specified cladding is stucco, EIFS or cultured stone veneer, at the bottom of the mat, place a foundation weep screed. Weather barrier and mat may be placed over top of the back leg of the weep screed to create the proper shingle effect and support moisture drainage.

Storage & Handling
WaterWay 9714 should be stored at temperature between 50 degrees to 90 degrees, out of direct sun light.