Wall section showing the WaterWay rainscreen mat behind the stucco and Stuc-O-Flex finish.

Choosing the Right WaterWay Drainage Mat Thickness

TLDR

WaterWay comes in three published thicknesses for wall assemblies: 3mm (nominal 1/8 inch), 7mm (nominal 5/16 inch), and 11mm (nominal 7/16 inch). All three carry the same filter fabric, the same vapor permeance, the same drainage claim, and the same list of approved claddings, so no thickness is a lesser product. The choice comes down to three things: the cladding going over it, how much added depth the openings, trim, and terminations can absorb, and how much drainage and ventilation space the assembly needs. When a project sits between two profiles, the specific call belongs with technical support and the assembly drawings.

A rainscreen drainage mat does one job: it holds the cladding off the weather resistive barrier, so water that gets behind the face has a path out, and air can move through the gap. Picking one is usually not the hard part. However, picking the thickness is, because the spec leaves the profile as a blank to fill in.

What a Rainscreen Drainage Mat Cavity Does

Every cladding lets some water past the face over the life of a wall. Joints, penetrations, window perimeters, and wind-driven rain all put incidental moisture behind the finish. The cavity handles that water in two ways.

  1. Bulk drainage. Water that reaches the back of the cladding drops through the open space and exits at a foundation weep screed, a “J” weep, or flashing with weeps at the base of the wall. It never has to sit against the WRB waiting to dry.
  2. Ventilation and drying. The same open space lets air move behind the cladding, which dries the back of the stucco or stone and the face of the WRB between wetting events. That supports two-way drying: the wall can shed moisture outward through the cavity as well as inward.

The assembly is designed to keep water out of the stucco layer in the first place. The cavity is the backstop for whatever still gets past the face: it gives that water a way out and shortens the drying time. That is also why a drained cavity belongs in any plan for how to stop stucco cracking.

The Three Thicknesses

All three profiles are published on individual data sheets in the product data sheets library. The nominal figures below are taken directly from those sheets.

ProfileNominal thicknessWidth (less flap / with flap)Area per rollAverage roll diameter
WaterWay 3mm1/8 inch / 3mm58 in / 62 in180 sq ft10 in
WaterWay 7mm5/16 inch / 7mm58 in / 62 in180 sq ft13 in
WaterWay 11mm7/16 inch / 11mm58 in / 62 in180 sq ft16 in

Every roll covers the same 180 sq ft at the same width, so the material takeoff does not change with profile. What changes is the depth of the space behind the cladding and the bulk of the roll on the scaffold.

Each profile is built the same way: a polymer core of fused, entangled filaments bonded to a moisture-resistant filter fabric on the outer surface. The fabric faces out toward the cladding and keeps the core clear so the drainage path stays open. The full product family is on the WaterWay Rainscreen Mat page.

What Actually Drives the Choice

The data sheets do not publish a rule that ties thickness to climate zone, cladding weight, or wall height, and we are not going to invent one here. What the published documents do support is a clear set of tradeoffs. More thickness gives more open space for water and air. It also puts more depth into every opening, trim piece, and termination on the wall.

Cladding: stone and stucco are on every sheet

All three profiles list the same recommended applications: the WaterWay Drainable Stucco Assembly, traditional stucco, manufactured and natural stone, EIFS, fiber-cement and lap siding, brick, below-grade drainage, and roofing. The 3mm is not limited to lighter claddings, and the 11mm is not reserved for stone.

So cladding type does not pick the thickness on its own. What it does change is the detailing at the base of the wall and the build-out stacked on top of the mat:

  • Stucco, EIFS, and cultured stone veneer terminate at a foundation weep screed. The WRB and mat both lap over the back leg of the screed so water sheds to the exterior.
  • Other claddings get a continuous strip of insect screen along the bottom edge of the mat, per Section 07460, folded over the outward face and held with a large head nail until the cladding goes on. Top vented walls get the same treatment at the top edge.
  • Traditional three-coat stucco already adds a 3/4 inch minimum scratch and brown coat in the WaterWay Rainscreen Stucco Assembly spec. The mat thickness adds to that, so the accessories and trim have to account for both.

For stone, the assembly drawings library includes a manufactured stone drainage detail, which is the right starting point before choosing a profile for a veneer wall.

Detailing: a thicker mat means more to detail

This is the tradeoff that matters most in the field. Every fraction of an inch of mat is a fraction of an inch the cladding moves away from the WRB, and that depth has to be absorbed somewhere at every edge of the wall.

  • Window and door returns. The mat is cut tight to the vertical part of each casing. A deeper mat pushes the cladding plane further out relative to the window frame, which changes the return depth, the sealant joint, and how the head flashing projects past the finished face.
  • Trim and accessories. Casing beads, corner beads, and screeds have to land the finished surface where the design expects it. Plan the accessory depth with the mat included from the start.
  • Wall ends on vented walls. Section 07460 calls for wall ends to terminate at a furring strip of matching thickness, so the strip has to be sized to the profile you choose. The same section adds a wood termination strip along the outside edge of each wall as a wind dam for negative wind load.
  • Penetrations. Electrical boxes, hose bibs, vents, and mechanical units all get the mat butted tight around them. More depth means more gap to close with the cladding and sealant.

A 3mm profile adds the least depth at those transitions. An 11mm profile gives the most open space but asks for the most deliberate detailing at every opening. The 7mm sits between them on both counts. Our guide to window flashing standards for elastomeric stucco walls covers WRB integration at openings, which has to be finished before any mat goes over it.

Drainage and ventilation capacity

A deeper cavity holds more open volume for water to fall through and air to move through. That is the physical case for a thicker profile on walls where drying capacity is the priority. There is no published drainage rate that differs by thickness, though. The drainage figure is the same across the line, so thickness is a question of cavity volume and detailing.

Working through the call

Some jurisdictions and project specifications set a minimum rainscreen cavity depth, and where one applies it decides the profile before any other factor does. Beyond that, it helps to have answers to these questions on paper:

  • What cladding goes over the mat, and what does it add in build-out thickness?
  • How much added depth can the window and door returns, trim, and accessories take without redesign?
  • Is the wall designed as a vented wall, with furring or termination strips at the ends?
  • Does the local code or the project spec set a minimum cavity depth?
  • How exposed is the wall, and how much drying capacity does the design team want behind it?

Those answers, plus a wall section, are what our technical team needs to recommend a profile. The assembly drawings are the best place to test a profile against the actual details before it goes into the spec.

What the Thickness Does Not Change

A thinner mat is not a lesser product. The performance data on all three data sheets is identical, because the filter fabric and core construction are the same across the line.

PropertyTest methodPublished value, all three profiles
Moisture vapor transmissionASTM E-96Exceeds 247 perms
DrainageCompared with standard WRBs50 times faster at draining water
WRB acceptanceICC/IRC AC-38Exceeds acceptance criteria for weather-resistive barriers
Ponding waterAC-38 Sec. 4.2.2Pass
Hydrostatic head pressureAATCC 12710 cm / 18 hours (equal to 70-mph wind)
Water resistance (boat test)ASTM D-779Vapor transfer: 12 min; no water after 96 hours
Filter fabric weightEN 1849-12.21 oz/yd2 (75 g/m2)
Filter fabric mean tensile strengthEN 12311-1181.58 lbs/ft (2.65 kN/m)
Filter fabric mean elongation at breakEN 12311-175%
Open space within cavityPublished feature90%
Recycled contentPublished featureUp to 40%, LEED credits

Two of those numbers deserve a note for the specifier.

The perm rating matters because the mat sits directly against the WRB. At more than 247 perms, it should never be the layer that slows vapor from leaving the wall, whichever profile is specified.

The AC-38 figure matters because the filter fabric is doing more than keeping the core clear. It is tested against the same acceptance criteria as a water-resistive barrier, which is why it is described as giving the substrate more protection behind the cladding.

Installing Any WaterWay Profile

The installation sequence is the same at every thickness. Most field problems on a rainscreen wall come from these steps.

Before the mat goes up, the contractor confirms that:

  • The substrate is sound, with no voids or protrusions that would interfere with the drainage plane.
  • The substrate is flat or plumb within 1/4 inch in a 4-foot radius.
  • Windows and doors are flashed and sealed, and roof flashings are installed.
  • The WRB is installed to allow drainage without water penetration.

During installation:

  • Attach the mat fabric side out, with the flap down for proper shingling.
  • For horizontal application, work from bottom to top. For vertical application, work from a corner.
  • Butt the edges tightly together.
  • Keep the mat flat against the wall with corrosion-resistant fasteners until the cladding is on.
  • Cut tight to casings at every opening without cutting or damaging the WRB.
  • Lap the WRB and mat over the back leg of the weep screed, termination bar, or flashing at the base.

Scheduling and storage:

  • Get the cladding on promptly. Section 07460 caps exposure at 30 days before cladding installation.
  • On site, store rolls between 50 and 90 degrees, out of direct sunlight. Section 07460 also notes that extreme cold makes the material firm.

Specifying the Mat in a Stucco Rainscreen Assembly

On a stucco rainscreen, the mat is specified as part of the WaterWay Rainscreen Stucco Assembly under CSI Section 09 24 00 / 09220: Portland cement plaster with Stuc-O-Flex Elastomeric Acrylic Finish and WaterWay Rainscreen and Ventilation Mat, with Therm-Flash flashing and a polymer-modified base coat as optional components. For claddings other than stucco, or when the drainage layer is specified on its own, the mat has a standalone section, 07460 Rainscreen Drainage Mat.

A few notes for the project manual:

  • Fill in the profile blank. The stucco spec leaves “WaterWay Drainage & Ventilation Mat Profile #” open. Choose the thickness during design, and make sure the details and accessories are drawn to the same profile.
  • Carry the finish requirements through. The finish over the assembly needs substrate moisture not exceeding 19% at application, ambient temperature of 40F or greater held for a minimum of 24 hours, and control joints laid out so no panel exceeds 144 sq ft of wall surface.
  • Include the finish data in the submittal. The tested figures for the Stuc-O-Flex Elastomeric Acrylic Finish are on its data sheet.
  • Coordinate flashing first. WRB integration at every window, door, and louver opening has to be complete before the mat goes over it.

Specs in PDF and editable formats are in the specifications library. For project types and references, see our commercial applications page.

Frequently Asked Questions

How thick should a rainscreen drainage mat be?

WaterWay is published in three thicknesses for walls: 3mm (nominal 1/8 inch), 7mm (nominal 5/16 inch), and 11mm (nominal 7/16 inch). The right one depends on the cladding, how much added depth the openings and trim can absorb, and how much drainage and ventilation space the assembly needs. Local code can also set a minimum cavity depth that determines it.

What is the difference between 3mm, 7mm and 11mm WaterWay?

The difference is cavity depth and roll size. All three share the same filter fabric, the same 247-plus perm rating, the same drainage claim, and the same list of approved claddings.

Does a thicker drainage mat drain better?

No. A thicker mat gives more open space for water and air, but the published drainage figure is the same for every profile: 50 times faster at draining water than standard weather resistive barriers. Thickness changes cavity volume and detailing. It does not change the product grade.

Can you use a rainscreen mat behind stone veneer?

Yes. Every WaterWay profile is designed for use with manufactured and natural stone, as well as traditional and one-coat stucco. With cultured stone veneer, the mat terminates at a foundation weep screed at the base of the wall, with the WRB and mat lapped over the back leg.

What perm rating does WaterWay have?

WaterWay exceeds 247 perms per ASTM E-96. That figure is the same across the 3mm, 7mm, and 11mm profiles, so vapor permeance is not a reason to choose one thickness over another.

Talk Through the Profile Before It Goes Into the Spec

The thickness decision is easiest to make with a wall section in front of you. Our technical team can review the cladding, the opening details, and any code requirements on the project and recommend a WaterWay profile. Call (800) 305-1045 or contact us with the drawings.

Get In Touch

Need Help With Your Project?

Whether you’re specifying a system, planning a project, placing an order, or looking for a local distributor, our team is here to help. We can assist with product selection, application methods, wall assemblies, pricing, order support, and shipment coordination.